Man Scilab

repfreq
Scilab Function

repfreq - frequency response

Calling Sequence

[ [frq,] repf]=repfreq(sys,fmin,fmax [,step])
[ [frq,] repf]=repfreq(sys [,frq])
[ frq,repf,splitf]=repfreq(sys,fmin,fmax [,step])
[ frq,repf,splitf]=repfreq(sys [,frq])

Parameters

Description

repfreq returns the frequency response calculation of a linear system. If sys(s) is the transfer function of Sys , repf(k) equals sys(s) evaluated at s= %i*frq(k)*2*%pi for continuous time systems and at exp(2*%i*%pi*dt*frq(k)) for discrete time systems ( dt is the sampling period).

db(k) is the magnitude of repf(k) expressed in dB i.e. db(k)=20*log10(abs(repf(k))) and phi(k) is the phase of repf(k) expressed in degrees.

If fmin,fmax,step are input parameters, the response is calculated for the vector of frequencies frq given by: frq=[10.^((log10(fmin)):step:(log10(fmax))) fmax];

If step is not given, the output parameter frq is calculated by frq=calfrq(sys,fmin,fmax) .

Vector frq is splitted into regular parts with the split vector. frq(splitf(k):splitf(k+1)-1) has no critical frequency. sys has a pole in the range [frq(splitf(k)),frq(splitf(k)+1)] and no poles outside.

Examples


A=diag([-1,-2]);B=[1;1];C=[1,1];
Sys=syslin('c',A,B,C);
frq=0:0.02:5;w=frq*2*%pi; //frq=frequencies in Hz ;w=frequencies in rad/sec;
[frq1,rep] =repfreq(Sys,frq);
[db,phi]=dbphi(rep);
Systf=ss2tf(Sys)    //Transfer function of Sys
x=horner(Systf,w(2)*sqrt(-1))    // x is Systf(s) evaluated at s = i w(2)
rep=20*log(abs(x))/log(10)   //magnitude of x in dB
db(2)    // same as rep
ang=atan(imag(x),real(x));   //in rad.
ang=ang*180/%pi              //in degrees
phi(2)
repf=repfreq(Sys,frq);
repf(2)-x
 
  

See Also

bode ,   freq ,   calfrq ,   horner ,   nyquist ,   dbphi ,  

Author

S. S.

Back